Comtech EF Data CDM-625A User Manual
Page 495
CDM-625A Advanced Satellite Modem
MN-CDM625A
CDM-625A ODU (Transceiver, BUC, LNB) Operation
Revision 3
10–27
Selection
Setting
Att
(Attenuation) 0 to 20 dB, in increments of .25dB. Limit and increments are variable
based upon unit Info string.
Amp
(Amplifier setting) Off or On
Mute
(Mute Mode) Disabled(i.e., Tx off) or Enabled (i.e., Tx on)
Att-Offset
(Attenuation Offset) 0 to 20 dB, in .25 dB increments
Press ENTER when done.
ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs
Online/Offline LPOD) Cnfg LNB
LNB Current: Src=On SwitchBiasTee=Thru
Window:30% Alarm=Disabled Cal=No()
Use the
◄ ►
arrow keys to select a setting, and then use the
▲▼
arrow keys to edit the setting:
Selection
Setting
Src
(LNB Current Source) Disabled or Enabled.
SwitchBiasTee
Off (mute LNB) or Thru (unmute LNB).
Window
(LNB Current-Window) Selecting a value from 20% to 50% defines the allowable
LNB Current change before declaring a fault. Selecting 99% disables the Current
Window function.
Alarm
(LNB Current Window Alarm Enable ) Disable or Enable the current window
alarm.
Cal
(Calibrate-LNB-Current ) Select Yes and press ENTER to calibrate the LNB current.
(Default is No.)
Note: LNB Current Source must be Enabled before the LNB current can be
calibrated.
Press ENTER when done.
ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs
Online/Offline LPOD) Cnfg Mask
Mask: LFRFPwr=Masked ERLD=Masked ()
FanSpd=Masked LNBCD=Alarm LNB22V=Masked
First, use the
◄ ►
arrow keys to select LFRFPower (Low Forward RF Power), ERLD (External
Reference Lock detect), FanSpd (Fan Speed), LNBCD (LNB Current Detect), or LNB22V (LNB 22V
Power Supply)
Then, for each selection, use the
▲▼
arrow keys to set that alarm to Fault, Alarm, or Masked.
Press ENTER when done.