Comtech EF Data CDM-625A User Manual
Page 371
CDM-625A Advanced Satellite Modem
MN-CDM625A
Serial-based Remote Product Management
Revision 3
8–59
Parameter
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
BUC
Temperature
N/A
4 bytes
Query only.
Returns BUCTemperature in the form sxxx, where:
s=sign (+ or –)
xxx=value
Note: This query is only valid when the FSK and BUC power are turned On.
N/A
BUT?
Exception –
600L Emulation:
ODT?
BUT=sxxx
(see Description of
Arguments)
BUC
Phase Lock
Loop
N/A
1 byte, 0 or 1
Query only.
Returns BUC phase lock loop in the form x, where:
0=Locked
1=Unlocked
Note: This query is only valid when the FSK is enabled.
N/A
BPA?
Exception –
600L Emulation:
OLL?
BPA=x
(see Description of
Arguments)
BUC Software
Version
N/A
2 bytes
Query only.
Returns BUC firmware version in the form xx, where:
xx=Value from 00 or 15.
Note: This query is only valid when the FSK and BUC power are turned On.
N/A
BSV?
Exception –
600L Emulation:
OSV?
BSV=xx
(see Description of
Arguments)
BUC
Power Class
N/A
2 bytes
Query only.
Returns BUC Power Class in the form xx, where:
xx=Power Class, in watts.
Note: This query is only valid when the FSK is enabled.
Example: <0/BPC? >0000/BPC=25
N/A
BPC?
Exception –
600L Emulation:
OPC?
BPC=xx
(see Description of
Arguments)