4 web server (http) interface, 1 user login – Comtech EF Data CDM-800 User Manual
Page 64

CDM-800 Gateway Router
Revision 1
Ethernet-based Remote Product Management
MN-CDM800
5–4
The user defines two Community Strings for SNMP access:
• Read Community
default = public
• Write Community
default = private
For proper SNMP operation, the CDM‐800 MIB files must be used with the
associated version of the CDM‐800 router M&C. Refer to the CDM‐800 FW Release
Notes for information on the required FW/SW compatibility.
5.4
Web Server (HTTP) Interface
A user‐supplied Web browser allows the full monitoring and control (M&C) of the CDM‐800
from its Web Server Interface. This embedded Web application is designed for, and works best
with, Microsoft Internet Explorer Version 7.0 or higher.
5.4.1 User Login
Type the CDM‐800 Management IP Address (shown here as http://xxx.xxx.xxx.xxx) into the
Address area of the user PC Web browser:
The login page opens.
Enter the assigned User Name and
Password – the default for both is
comtech. Click [Log On].
If the User Name and Password are
accepted: The CDM‐800 Gateway Router
Web Server Interface Home page, similar
to the example shown here, appears: