Comtech EF Data CDM-800 User Manual
Page 117

CDM-800 Gateway Router
Revision 1
Serial-based Remote Product Management
MN-CDM800
6–9
These Instruction Codes are explained in complete detail in the tables that follow. Note that the Target‐to‐Controller Instruction Code
Qualifiers, described earlier, that appear in the “Response to Command” column carry the following meanings:
= Message OK.
? Received OK, but invalid arguments were found.
* Message OK, but not permitted in current mode.
# Message OK, but unit is not in Remote mode.
! Invalid instruction.
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Default
Passwords
DPW= N/A
Command Only.
Resets the admin username/password to:
Username = “comtech”
Password = “comtech”
DPW=
DPW?
DPW*
DPW#
N/A
N/A
GE1 Address
IG1=
18 bytes numerical Command or Query.
Sets the IP Address and network prefix for the 10/100/1000 BaseT GE1 Ethernet
port, in the form aaa.bbb.ccc.ddd/yy, where:
(Permitted ranges – cannot all be zero)
aaa = 0-223
bbb = 0-255
ccc = 0-255
ddd = 0-255
yy = network prefix (range: 8 to 31)
Other restrictions:
If aaa>191, prefix may not be less than 24.
If aaa>127, prefix may not be less than 16.
Example: IG1=010.006.030.001/24
IG1=
IG1?
IG1*
IG1#
IG1?
IG1=xxx.xxx.xxx.xxx/yy
(see Description of Arguments)