beautypg.com

1 dc operation – applying power – Comtech EF Data CDM-800 User Manual

Page 49

background image

CDM-800 Gateway Router

Revision 1

Rear Panel Connections

MN-CDM800

3–13

3.3.3

48V Direct Current (DC) Power Interface (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-8. CDM-800 DC Power Interface

3.3.3.1 DC Operation – Applying Power

 
 
 
 
 
 
 
 
 
 

Figure 3-9. Applying DC Power to the CDM-800

To apply DC power to the CDM‐800: 
 

First,  connect  the  user‐supplied  (+)  and  (–)  DC  power  leads  to  their  respective 

terminals. Number 18 AWG minimum wires are recommended.  
 

Then, connect the user‐supplied DC power leads to the power source. 

 

Finally, switch the unit ON.  

Feature

Description

1

On / Off Switch

2

Screw‐in Fuse Holders / Receptacles

3

Power Terminal Block 

  

DC Power Specifications 

Input Power 

25W (typical)
245W (maximum with BUC) 

Input Voltage 

48V DC, nominal
(36V to 60V) 

Connector Type

Terminal Block

Fuse Protection 

(2X) 20mm Slow‐blow type fuses:
T3A (3.0A) Main  
T5A (5.0A) (BUC)