3.3.2.2 AC Operation – Replacing Fuses

 

FOR  CONTINUED  OPERATOR  SAFETY,  ALWAYS  REPLACE  THE  FUSES  WITH  THE 
CORRECT TYPE AND RATING. 

 
The CDM‐800 uses two 20mm Slow‐blow fuses – one each for line and neutral connections. The 
fuses are located in the rear panel at the power supply (Figure 3‐7). 
 

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING! 

The  fuses  are  contained  within  a  fuse  holder  that  is  press‐fit  into  the  body  of  the  IEC  power 
module. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3-7. Replacing CDM-800 AC Fuses

 
To replace the fuses: 

 

First, unseat the fuse holder from the IEC power module. 

 

o

Use the slot to pry the holder outward from the IEC power module.  
 

o

Pull the holder straight out, and then swing the holder away from the module.  

 

Then, remove and replace the fuses as needed. 

 

o

Use T2.5A (2.5 Amp) fuses for standard operation. 
 

o

Use T4.5A (4.5 Amp) fuses when a Block Upconverter (BUC) is installed. 

 

Finally, re‐seat the fuse holder in the IEC power module.