3 remote commands and queries – Comtech EF Data CDM-800 User Manual
Page 116

CDM-800 Gateway Router
Revision 1
Serial-based Remote Product Management
MN-CDM800
6–8
6.3
Remote Commands and Queries
The Serial Command Line interface (CLI) (the Controller), shown previously in Figure 5‐1, is used to issue remote commands and queries
to the CDM‐800 (the Target). From the CLI command prompt CDM‐800> type in the command or query packet, using the format
explained previously, for transmission to the CDM‐800.
For example: CDM‐800><0000/LC1=3[cr]
The table that follows provides a ‘quick reference‘ to the Instruction Codes available at present for M&C of the CDM‐800. The ‘C’ and ‘Q’
columns, when marked with an ‘X’, denote whether that Instruction Code is Command Only, Query Only, or Command and Query.
INSTRUCTION
CODE
USED TO...
C
Q
Page
DPW
Set default passwords
X
5‐9
IG1
Set or query the IP Address and network prefix for the GE‐1 10/100/1000 Gigabit Ethernet Port
X
X
5‐9
IG2
Set or query the IP Address and network prefix for the GE‐2 10/100/1000 Gigabit Ethernet Port
X
X
5‐10
IPA
Set or query the IP Address and network prefix for the FE (10/100 Fast Ethernet) port
X
X
5‐10
LC1
Set or query the link configuration for the GE‐1 10/100/1000 Gigabit Ethernet Port
X
X
5‐10
LC2
Set or query the link configuration for the GE‐2 10/100/1000 Gigabit Ethernet Port
X
X
5‐10
MAC
Query the unique router MAC Address
X
5‐11
MG1
Query the unique GE‐1 port MAC Address
X
5‐11
MG2
Query the unique GE‐2 port MAC Address
X
5‐11
MLC
Set or query the link configuration for the FE Port
X
X
5‐11
NPS
Query the negotiated port speeds for the GE‐1, GE‐2, and FE ports
X
5‐11
SRC
Set or query the SNMP Read Community String
X
X
5‐11
SWC
Set or Query the SNMP Write Community String
X
X
5‐11