Electrical Trouble Shooting

••

51

Electrical Trouble Shooting

Power Up / Sign On / Communications

Problem

Probable Cause

Corrective Action

Machine fails to power up

with no light present in
the AC power switch.

1) Incorrect power amplitude.

1) Confirm that the AC entry is configured for the

line voltage intended to be applied to the
machine. Failure to do so can damage the
machine's internal power supply. Refer to the
"Fuse Configuration".

2) Lack of power to machine.

2) Check that both ends of the power cord are

plugged in securely.

2A) Confirm that the outlet the machine is plugged

into has power.

3) Missing or blown fuse(s)

3) Check that the fuse(s) located inside the AC

entry are present and intact. Replace as needed.
Refer to the "Fuse Configuration".

Machine fails to power up

with light present in the
AC power switch.

1) Unconnected cable / connector

inside machine.

1) Power off and remove the power cord from the

AC entry. Remove the back cover and inspect
the cables and connectors to and from the power
supply. Refer to the "Electrical System
Schematic".

2) Thermal Control Board

unplugged from the Mother Board

2) Power off and remove the power cord from the

AC entry. Remove the back cover and reseat the
Thermal Control Board.

Front panel displays no text

or nothing at all.

1) Front panel cable unplugged.

1) Power off and remove the power cord from the

AC entry. Remove the back cover and inspect
the cable and connectors to and from the front
panel. Refer to the "Electrical System
Schematic".