Printer Unpacking / Installation

Fuse Configuration

The main fuse(s) on the AVERY DENNISON 676 are located inside the AC power
entry receptacle. The entry has a fuse drawer that holds the fuse(s) and selects the
appropriate line voltage. If the number in the window DOES NOT match the AC
line intended to be supplied to the printer, DO NOT plug the power cord in. Re
configure as follows:

1) Using a flat blade screwdriver, open the AC entry by lifting the tab just above the

voltage indicator window.

WARNING: Attempting to open the AC entry with the AC power cord inserted into

it will cause damage to the AC entry.

2) Remove the red fuse drawer.

3) Remove all fuses and the fuse jumper if it is present.

4) Insert into the fuse drawer the correct number and style of fuses and fuse jumper

for your application.

Configuration Number One:

Line voltage between the range of

90 - 132VAC @ 50 - 60Hz 1 Ph

1) Install one 921167 - 10.0A 250V Fast Acting 1/4 x 1 1/4"

2) Install one Fuse Jumper

See Figure FUSE1

Configuration Number Two:

Line voltage between the range of

180 - 265VAC @ 50 - 60Hz 1 Ph

1) Install two 921168 10.0A 250V Fast Acting 5 x 20MM

NOTE: The fuse jumper must be removed to install both 5 x
20mm fuses.

The fuses must be between points A and B as shown not B and C.

See Figure FUSE2

Location of 115V Text

Location of 230V Text

Two 5 x 20MM Fuses One Each Side

FIGURE FUSE2

One 1/4 x 1 1/4" Fuse Far Side

Location of 115V Text

Location of 230V Text

Fuse Jumper

FIGURE FUSE1

5 x 20 mm fuse

FRONT

FRONT

A

B

C

5) Reinsert the fuse drawer into the AC entry with the desired voltage up.

6) Close the AC entry and verify the correct voltage is now visible.