2 ascender 32 – Analog Way ASCENDER 16 (LIVECORE) - Ref. ASC1602 User Manual User Manual
Page 24
24
4.9.2 Ascender 32
• Cooling air flows from front side to rear.
• Max ambient operating temperature: < 40°C (< 104°F).
• Operating temperature: 0 to +40°C / +32°F to +104°F
• Storage temperature: -40 to +70°C / -40°F to +158°F
• Operating humidity: 10 to 80% (non condensing)
• Input voltage range: 100-240 VAC autosensing, 50/60 Hz
• Typical consumption: Ascender 32: 345 W
4.9.2 Ascender 32
Dimensions:
W 482 x D 552 x H 177 mm with rack mount and handles
19”W x 23.73”D x 6.97”H
W 445 x D 552 x H 177 mm without rack mount and handles
17.52”W x 23.73”D x 6.97”H
Weight:
19,4 kg / 42.77 lbs
(Compatible with a Standard
19” rack, Height = 4 U)
ELECTRICAL SECURITY:
• IEC 60950-1:2005 (2nd Edition); Am 1:2009
• EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011, CSA C22.2; National Differences specified in the CB
Test Report
• UL listed (Canada & US)
ELECTROMAGNETIC COMPATIBILITY:
• IEC 61000-3-2 (2009)
• IEC 61000-3-3 (2008)
• CISPR22 (2008)
• CISPR24 (2010)
• FCC Part15 of 2012
• IECS-003 of August 2012
ENVIRONMENT:
• RoHS
• WEEE
USE/TRANSPORT:
• ETS 300 019-2-2: Environmental conditions and environmental tests for telecommunications equipment ;
Part 2-2 : specification of environmental tests ; Transportation ; Specification T 2.3: Public transportation
• ETS 300 019-2-3: Environmental conditions and environmental tests for telecommunications equipment ;
Part 2-3 : specification of environmental tests ; Stationary use at weather protected locations ; Specification
T 3.1 and T 3.1 E: Temperature-controlled locations
If your device should lose power unexpectedly, you may lose any unsaved settings.