Table A-7
SCPI Commands for Power
Function
SCPI Command
Description
Parameter and
Range
Query
Shutdown
Logic Control
[:]OUTPut:POLarity
Sets the TTL level that will
trigger an External
Shutdown.
?|HIGH|LOW
Yes
Main Output
Control
[:]OUTPut[:POWer][:STATe]
Control Main Output State
(Enable/Disable)
?|ON|OFF
Yes
Power On
Main Output
Control
[:]OUTPut[:POWer]:PON[:STATe]
Control Main Output
Autostart State (Enable/
Disable)
?|ON|OFF
Yes
Aux Output
Control
[:]OUTPut:AUXilliary[:STATe]
Control Aux Output State
(Enable/Disable)
?|ON|OFF
Yes
Power
Auxiliary
Output Control
[:]OUTPut:AUXilliary:PON[:STATe]
Control Aux Output
Autostart State (Enable/
Disable)
?|ON|OFF
Yes
Table A-8
SCPI Commands for Triggering
Function
SCPI Command
Description
Parameter and
Range
Query
Set Immediate
Initiation of
Trigger System
[:]INITiate[
Triggers the Autosequence
Program.
N/A