Resistive-controlled voltage apg setup – AMETEK XG Family Programmable DC User Manual
Page 115

Analog Programming
(APG) and Isolated Analog Programming (ISOL)
M370430-01 Rev E
4-15
4
Resistive-Controlled Voltage APG Setup
To activate APG voltage mode using an external resistor:
1.
Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the mode control is already
at the VAP position.
is displayed on the output voltage display.
2.
Turn the rotary Adjust/Enter control to select
(resistor
source from non-isolated connector).
3.
Press the rotary Adjust/Enter control to commit the selected
mode.
is displayed on the output voltage display.
4.
Select the input source level using the rotary Adjust/Enter
control.
5.
Once the desired level has been selected, press the rotary
Adjust/Enter control to commit the change.
The display will return to the normal display.
Deactivating APG Voltage Mode
To deactivate the APG voltage mode:
1.
Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the mode control is already
at the VAP position.
2.
is displayed on the output voltage display.
3.
Turn the rotary Adjust/Enter control to select
.
4.
Press the rotary Adjust/Enter control to commit the change.