Remote
Operation
5-66
M370430-01 Rev E
4.
From the Hyper Terminal (or any other terminal program)
select the Transfer>Send Text File...
5.
Navigate to and select the text file that was previously stored.
Click the Open button.
6.
Execute the program recording stop command:
:PROG:STOP
7.
Execute the readback command to verify the entire program
was transferred correctly:
PROG:READ?
8.
Set the data rate back to the original speed.
9.
Close the connection to the HyperTerminal program and
configure the connection data rate to be the original speed.
Running an Auto Sequence Program
Once an auto sequence program has been stored, there are a few
commands that can be used to run the program. Once a program begins
running, it will continue running until completion and then repeat the
number of times specified by the repeat command. The default at power
on is to have repeat set to 1.
Commands:
*TRG
[:]INITiate[
[:]PROGram[
Where:
RUN
causes the program to begin execution.
STOP
causes the program to stop execution
PAUSe
causes the program to stop executing at the current command. If
a subsequent run is sent, the program will resume executing with the
next command in the program.
For Example:
:PROG:STAR
*IDN?
*IDN?
:PROG:STOP
:PROG:STAT RUN
The output after the last command might be as follows:
AMETEK, XG 150-5.6, SN# E00123456, 1.00 Build 10, 21/
11/2005
AMETEK, XG 150-5.6, SN# E00123456, 1.00 Build 10, 21/
11/2005
Important:
Execution of the program may be terminated at any time by
pressing the Esc key in the MS Windows Hyper Terminal window. The power
supply can be controlled during program execution.