5-15

LOAD ON Voltage

Purpose:
LOAD ON voltage level query command.

Command Syntax:
LDON?{;|NL}

Description:
LDON? returns the present load on voltage of SLH-series electronic load module.

LOAD OFF Voltage

Purpose:
LOAD OFF voltage level query command.

Command Syntax:
LDOF?{;|NL}

Description:
LDOF? returns the present load off voltage of SLH-series electronic load module.

LEVEL HIGH/LOW

Purpose:
Static mode's LEVEL low or high status query command or active LEVEL of AC electronic load
query command.

Command Syntax:

LEVE?{NL}

Description:
LEVE? returns the present level status, “0” indicates LEVEl LOW, and “1” indicates LEVEl HIGH.

PRESET ON/OFF

Purpose:
PRESet ON or OFF status query command.

Command Syntax:
PRES?{NL}

Description:
PRES? returns the present preset status, “0” indicates PRESet OFF, and “1” indicates PRESet ON.

MODE

Purpose:
CC, CR, CV or CP operating mode query command.
Command Syntax:
MODE?{NL}

Description:
MODE? returns the present operating mode status, ”0” indicates CC MODE, ”1” indicates CR