Sorensen SLD-Series DC Load

Introduction

M540075-01 Rev C

1-9

• two 16-bit timers set current T

HIGH

and T

LOW

duration and feed into the DFT

• the DFG sends analog signals to the Load Control Circuit
• one of Constant Current (CC), Constant Resistance (CR), or Constant Voltage (CV)

and one range level is selected, depending on which mode and range are operating

• the drive circuit controls the load current flow through power MOSFET
• the current sense Amplifier, built into the power MOSFET stage, feeds the load

current signal to 16-bit DAM.

• the voltage V-sensing circuit selects the Load input terminal or V-sense BNC input,

depending on the CONFIG key's V-sense ON/OFF setting, and feeds the voltage
signals to 16-bit DVM

The 16-bit voltage and current meter digital bus feeds back to the CPU circuitry; each SLD-
series load module can transfer to chassis through isolated serial circuitry.