Applications

Sorensen SLD-Series DC Load

4-8

M540075-01 Rev C

4.7

Parallel Operation

When there is insufficient power or current rating on the electronic load module, two or more
electronic load modules can be paralleled to operate as one unit. A parallel connection can
extend the electronic load module to a higher power and current rating. In such a case, the
total load current and power is equal to the sum of the two (or more) load modules.

CAUTION:
Only channels with identical voltage polarity rating should be parallel
connected.


-

+

-

+

-

+

-

+

DC LOAD

I

I1

I2

I3

I4

* I = I1+I2+I3+I4

Figure 4-8 SLD-Series DC Plug-in Load Module Parallel Operation