Sorensen SLD-Series DC Load

Applications

M540075-01 Rev C

4-7

4.6

Connection for a Multiple Output Power Supply

RULE

for a multiple output power supply connection to the SLM-series DC electronic Loads:

The potential of positive input (Red binding post) must be greater than the potential of ground
input (Black binding post), and the potential of ground input must be greater than the potential
of negative input (White binding post).

Connect the positive (+) V-sense connector (RED) to the power source's positive output.
Connect the negative (-) V-sense connector (WHITE) to the power source's negative output.
Connect the ground (com) V-sense connector (BLACK) to the power source's common output.

Figure 4-7 is an example of +5V, -5V, +12V, -12V, +3.3V, +5V-sb, +40V and +24V Hex outputs
power supply connected to four SLD-series dual electronic load modules.

Figure 4-7 Example Connection, Six-output Power Supply to Four SLD-series Modules

in an SLM-4 Chassis