AMETEK SLD Series User Manual
Page 35
Sorensen SLD-Series DC Load
Operation
M540075-01 Rev C
3-7
18
-/+
DC INPUT Binding Posts
The negative (left) and positive (right) terminal of load input connector
•
Connect the red, positive (+) Load input connector to the power source’s positive
output.
•
Connect the white, negative (-) load input connector to the power source’s negative
output.
•
Connect the black, ground (com) output for a negative output power supply.
NOTE:
Before testing, ensure that the voltage and current do not to exceed the
maximum rating of each SLM-series DC load module and the connection method
utilized.
Also check the polarity of DC input connection before testing.
19 V
SENSE
Used to measure the specific voltage points through the V-sense BNC cable.
•
Connect the red, positive (+) V-sense connector to the power source’s positive
output.
•
Connect the white, negative (-) V-sense connector to the power source’s negative
output.
•
Connect the black, ground (com) V-sense connector to the power source’s
common output.
NOTE:
Use the CONFIG key to set the V
SENSE
function to ON.
I monitor (double bay unit only; see Figure 2-2)
Provides the load current waveform output to an oscilloscope to evaluate the current
waveform of a power supply under test.