beautypg.com

3 constant current (cc) mode application, 1 static mode, Constant current (cc) mode application – AMETEK SLD Series User Manual

Page 49

background image

Sorensen SLD-Series DC Load

Applications

M540075-01 Rev C

4-3

4.3

Constant Current (CC) Mode Application

The Constant Current mode is highly suitable for testing the Load Regulation, Cross Regulation,
Output Voltage and Dynamic Regulation of the power supply, and for testing the discharge
characteristic and the life cycle of the Battery.

4.3.1 Static

Mode:

Major application (see Figure 4-3):

• Voltage source testing.
• Power supply load regulation testing
• Battery discharge testing

VOLTAGE

SOURCE

ELECTRONIC LOAD

CC MODE

VOLTAGE

SOURCE

ELECTRONIC LOAD

CC MODE

DC

-

+

INPUT

-

+

DC

INPUT

I

HIGH

I

LOW

V

I

LOAD CURRENT

LOAD CURRENT

SETTING

V

I

LOAD CURRENT

DYNAMIC LOAD

CURRENT SETTING

Figure 4-3 Constant Current Mode Application