Resistance Programming of Output Current

Refer to Figure 4-7 for resistance programming of the output current.

1.

Set Position-7 of the SETUP switch to OFF for 0–5 VDC programming range.

2.

Connect the external programming resistance, 0–5 k

, to the REMOTE

ANALOG INTERFACE connector, from Pin-23 to Pin-22.

3.

Connect a jumper from Pin-22 to Pin-10.

8.

Program the other parameters to the desired limit values: VOLTAGE
PROGRAMMING INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3,
with respect to Pin-12. AUXILIARY 5VDC OUTPUT, Pin-15, could be used for
full–scale programming.

NOTE: Step 4 is mandatory. The power supply will not work properly without it.

4.

Connect Pin-1, ANALOG–CONTROL, of the REMOTE ANALOG INTERFACE
connector to Pin-6.

Figure 4-7. Resistance Programming of Output Current