beautypg.com

AMETEK DLM 600W Series User Manual

Page 68

background image

DLM 600W Series

M362161-01 K

4-10

4.4.3

Voltage–Source Programming of OVP

Refer to Figure 4-5 for setting up voltage–source programming of OVP.

1.

Set Position-6 of the SETUP switch to OFF for 0–5 VDC programming range.

2.

Set Position-6 of the SETUP switch to ON for 0–10 VDC programming range.

3.

Connect the external programming voltage source to the REMOTE ANALOG
INTERFACE connector, with positive to Pin-3 and negative to Pin-12.

6.

Program the other parameters to the desired limit values: VOLTAGE

PROGRAMMING INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT,
Pin-10, with respect to Pin-12. AUXILIARY 5VDC OUTPUT, Pin-15, could be
used for full–scale programming.

NOTE: Step 4 is mandatory. The power supply will not work properly without it.

4.

Connect Pin-1, ANALOG–CONTROL, of the REMOTE ANALOG INTERFACE
connector to Pin-6.

Figure 4-5. Voltage–Source Programming of OVP