AMETEK DLM 600W Series User Manual
Page 19

DLM 600W Series
M362161-01 Rev J
1-3
High resolution front panel controls for voltage and current
(10–turn potentiometers), and OVP (20–turn trimmer
potentiometer)
Preview switches for output voltage, current, and OVP to set
parameters without disrupting load connections
Front panel OUTPUT switch for on/off control of output power
Remote sensing to compensate for voltage drop of power leads
User selectable ranges of 0–5 VDC and 0–10 VDC for
programming and monitoring of output voltage and current,
and for programming OVP
SETUP switch for selecting ranges for programming and
monitoring signals
Opto–isolated remote shutdown for control of output power
Front panel LOCAL/REMOTE switch for selecting programming
source
LOCAL–LOCKOUT function to disable front panel control while
in remote operation
Digital I/O for remote control and status annunciation
Configuration changes without requiring removal of covers
Optional GPIB, LXI
TM
Class C Ethernet Interface, RS-232,
and isolated remote analog control
Cooling fan speed control for low noise and extended fan life
1.4 Specifications
1.4.1
DLM Series Product Matrix
Model
Voltage Range
Current Range
Power Rating
DLM 5–75
0–5 VDC
0–75 ADC
375W
DLM 8–75
0–8 VDC
0–75 ADC
600W
DLM 10–60
0–10 VDC
0–60 ADC
600W
DLM 20–30
0–20 VDC
0–30 ADC
600W
DLM 40–15
0–40 VDC
0–15 ADC
600W
DLM 60–10
0–60 VDC
0–10 ADC
600W
DLM 80–7.5
0–80 VDC
0–7.5 ADC
600W
DLM 150–4
0–150 VDC
0–4 ADC
600W
DLM 300–2
0–300 VDC
0–2 ADC
600W