2.5.2

Rack Mount Installation of Two DLM Series 600W Units

Follow the procedure below to install two (2) Sorensen DLM 600W Series power
supplies in a rack using the Rack Mount Kit, Sorensen part number DLMRK .
Refer to Figure 2-3.

1.

Remove the four (4) rubber feet and mounting hardware from the bottom of the
unit and discard.

2.

Remove the four (4) truss head screws (two on each side) from the front side
panels on both units. (Do not discard.)

3.

Install the Tie Bar onto the bottom of the two (2) inner heat sinks using the six (6)
Philips flat head screws, 6-32UNC-2A X .31” supplied in the kit.

4.

Install Rack Mount Extruded Ears on front sides of unit using existing four (4)
truss head screws.

5.

Position the two Chassis Rack Mount Brackets in the rack, use the two (2) Right
Angle Adapter Brackets, if required to match existing vertical rack rail positions.

CAUTION
To prevent internal damage, use the specified screw lengths only.