DLM 600W Series

M362161-01 Rev J

4-3

4.3 REMOTE ANALOG INTERFACE

The REMOTE ANALOG INTERFACE provides a means to remotely control and monitor
the operation of the power supply. Refer to Figure 4-2 for an illustration of the
connector, and Table 4–2 for pinout information.

Figure 4-2. Remote Analog Interface Connector

4.3.1

REMOTE ANALOG INTERFACE Connector

The REMOTE ANALOG INTERFACE connector is a 25–position female
subminiature–D type.

Pin No.

Function

Pin No.

Function

1

ANALOG–CONTROL Input

14

EXTERNAL–OFF Input (+)

2

EXTERNAL–OFF Return

15

Auxiliary 5 VDC Output (+)

3

OVP Programming Input

16

OVP Resistance
Programming Output

4

REMOTE–CONTROL Status Output

17

OVP Resistance
Programming Return

5

VOLTAGE–MODE Status Output

18

FAULT Status Output

6

Auxiliary 5 VDC Return

19

Voltage Monitor Output

7

Current Monitor Output

20

Voltage Resistance
Programming Return

8

Voltage/Current Monitor Return

21

Voltage Resistance
Programming Output

9

Voltage Programming Input

22

Current Resistance
Programming Output

10

Current Programming Input

23

Current Resistance
Programming Return

11 Not

Used

24 LOCAL–LOCKOUT

Input

12

V/I/OVP Programming Return

25

OVP Status Output

13 Not

Used

Table 4–2. Remote Analog Interface Connector Pinout