M362161-01 Rev J

4-11

4.4.4

Resistance Programming of Output Voltage

Refer to Figure 4-6 for setting up resistance programming of the output voltage.

1.

Set Position-8 of the SETUP switch to OFF for 0–5 VDC programming range

2.

Connect the external programming resistance, 0–5 k

, to the REMOTE

ANALOG INTERFACE connector, from Pin-20 to Pin-21.

3.

Connect a jumper from Pin-21 to Pin-9.

7.

Program the other parameters to the desired limit values: CURRENT
PROGRAMMING INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3,
with respect to Pin-12. AUXILIARY 5VDC OUTPUT, Pin-15, could be used for
full–scale programming.

NOTE: Step 4 is mandatory. The power supply will not work properly without it.

4.

Connect Pin-1, ANALOG–CONTROL, of the REMOTE ANALOG INTERFACE
connector to Pin-6.