beautypg.com

Operation – AMETEK DLM 600W Series User Manual

Page 47

background image

M362161-01 Rev J

3-1

SECTION 3

OPERATION

3.1 Introduction

The DLM Series power supplies have a full complement of controls, indicators, and
connectors that allow the user to easily install, setup, and operate the unit.

3.2 Controls and Indicators

Refer to Figure 3-1 for an illustration of the front and rear panel controls and indicators.

1.

VOLTAGE Display: 3.5 digit, 7–segment LED display that normally indicates the
output voltage. When the V/I PREVIEW switch is pressed, the display indicates
the programmed setting of output voltage. When the OVP PREVIEW switch is
pressed, the display indicates the programmed setting of OVP.

2.

CURRENT Display: 3.5 digit 7–segment LED display that normally indicates the
output current. When the V/I Preview switch is pressed, the display indicates the
programmed setting of output current.

3.

VOLTAGE Control: 10–Turn potentiometer for adjusting the output voltage.

4.

CURRENT Control: 10–Turn potentiometer for adjusting the output current.

5.

OVP SET Control: 20–Turn trimmer potentiometer for adjusting overvoltage
protection.

6.

POWER Switch: Push–on/Push–off switch for turning the unit on and off.

7.

OUTPUT Switch: Push–on/Push–off switch for turning the output on and off.

8.

V/I PREVIEW Switch: Momentary push–button switch for previewing the
programmed settings of output voltage and current. The programmed setting is
derived from the front panel controls, the analog interface, or the GPIB interface,
whichever has control.