AMETEK DLM 600W Series User Manual
Page 63

DLM 600W Series
M362161-01 Rev J
4-5
Analog Output Signals
REMOTE VOLTAGE MONITOR: Pin-19, readback of the output voltage is provided
with a 0–5 VDC or 0–10 VDC signal (user selectable with SETUP switch) indicating
0–100% of full scale output. Signal is referenced to Pin-8, and is not isolated from the
negative (return) output of the unit.
REMOTE CURRENT MONITOR: Pin-7, readback of the output current is provided with
a 0–5 VDC or 0–10 VDC signal (user selectable with SETUP switch) indicating 0–100%
of full scale output. Signal is referenced to Pin-8, and is not isolated from the negative
(return) output of the unit.
Auxiliary 5 VDC Output
AUXILIARY 5 VDC OUTPUT: Pin-15, 5 VDC logic supply output is available
referenced to the control circuit ground, Pin-6; not isolated from the negative (return)
output of the unit. Source resistance is 47
.
AUXILIARY 5 VDC OUTPUT RETURN: Pin-6, return for 5 VDC logic supply output;
referenced to the other signals of the REMOTE ANALOG INTERFACE; not isolated
from the negative (return) output of the unit.
Remote Analog Programming Input Signals
REMOTE VOLTAGE PROGRAMMING INPUT: Pin-9, an input signal of 0–5 VDC or
0–10 VDC (user selectable with SETUP switch) programs the output voltage 0–100% of
full scale. Signal is referenced to Pin-12, and not isolated from the negative (return)
output of the unit.
REMOTE CURRENT PROGRAMMING INPUT: Pin-10, an input signal of 0–5 VDC or
0–10 VDC (user selectable with SETUP switch) programs the output current 0–100% of
full scale. Signal is referenced to Pin-12, and not isolated from the negative (return)
output of the unit.
REMOTE OVP PROGRAMMING INPUT:
Pin-3, an input signal of 0–5 VDC or
0–10 VDC (user selectable with SETUP switch) programs the OVP threshold from
5–110% of full scale output voltage. Signal is referenced to Pin-12, and not isolated
from the negative (return) output of the unit.
REMOTE RESISTANCE VOLTAGE–PROGRAMMING OUTPUT:
Pin-21 connected
to Pin-9, REMOTE
VOLTAGE
PROGRAMMING
INPUT,
with an adjustable resistance of
0–5 k
connected between Pin-21 and Pin-20, programs the output voltage from
0–100% of full scale. Signals are not isolated from the negative (return) output of the
unit.