2 electrical specifications, Table 1–1. dlm series specifications – AMETEK DLM 600W Series User Manual
Page 20

DLM 600W Series
M362161-01 K
1-4
1.4.2
Electrical Specifications
DLM Series Electrical Specifications
1
Model
DLM 5-75 DLM 8-75 DLM10-60 DLM20-30 DLM40-15 DLM60-10 DLM80-7.5 DLM150-4 DLM300-2
Output Rating:
Output Voltage
Output Current
Output Power
0-5VDC
0-75ADC
375W
0-8VDC
0-75ADC
600W
0-10VDC
0-60ADC
600W
0-20VDC
0-30ADC
600W
0-40VDC
0-15ADC
600W
0-60VDC
0-10ADC
600W
0-80VDC
0-7.5ADC
600W
0-150VDC
0-4ADC
600W
0-300VDC
0-2ADC
600W
Line Regulation
2
:
Voltage (0.005% of Vmax + 2mV)
Current (0.01% of Imax + 2mA)
2.4 mV
9.5 mA
2.4 mV
9.5 mA
2.5 mV
8 mA
3 mV
5 mA
4 mV
3.5 mA
5 mV
3 mA
6 mV
2.8 mA
9.5 mV
2.2 mA
17 mV
2.1 mA
Load Regulation
3
:
Voltage (0.005% of Vmax + 2mV)
Current (0.02% of Imax + 5mA)
2.4 mV
20 mA
2.4 mV
20 mA
2.5 mV
17 mA
3 mV
11 mA
4 mV
8 mA
5 mV
7 mA
6 mV
6.5 mA
9.5 mV
5.8 mA
17 mV
5.4 mA
Remote Voltage-Programming Accuracy
Voltage (0.25% of Vmax)
Current (.5% of Imax)
OVP (1.0% of 1.1
Vmax)
20 mV
375 mA
55 mV
20 mV
375 mA
88 mV
25 mV
300 mA
110 mV
50 mV
150 mA
220 mV
100 mV
75 mA
440 mV
150 mV
50 mA
660 mV
200 mV
38 mA
880 mV
375 mV
20 mA
1.65V
750 mV
20 mA
3.3V
Display Accuracy:
Voltage (0.5% of Vmax + 1 count)
Current (1.0% of Imax + 1 count)
35 mV
850 mA
50 mV
850 mA
60 mV
700 mA
200 mV
400 mA
300 mV
160 mA
400 mV
110 mA
500 mV
85 mA
850 mV
50 mA
2.5V
30 mA
Preview Accuracy:
Voltage (1.0% of Vmax + 1 count)
Current (1.5% of Imax + 1 count)
OVP(1.0% of 1.1
Vmax+1 count)
60 mV
1.23A
65 mV
90 mV
1.23A
98 mV
100 mV
1.0 mA
120 mV
300 mV
550 mA
320 mV
500 mV
235 mA
540 mV
700 mV
160 mA
760 mV
900 mV
120 mA
980 mV
1.6V
70 mA
1.75V
4V
40 mA
4.3V
Ripple and Noise, Voltage-Mode:
RMS (20 Hz-20 MHz)
P-P (20 Hz-20 MHz)
5 mV
30 mV
5 mV
30 mV
5 mV
30 mV
2.5 mV
15 mV
2.5 mV
15 mV
2.5 mV
20 mV
4 mV
20 mV
7 mV
40 mV
10 mV
60 mV
OVP Adjustment Range:
5% to 110% of Vmax
0.25-5.5V
0.4-8.8V
0.5-11V
1-22V
2-44V
3-66V
4-88V
7.5-165V
15-330V
DLM Series Supplemental Characteristics
Stability
4
:
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
2.5 mV
37.5 mA
4 mV
37.5 mA
5 mV
30 mA
10 mV
15 mA
20 mV
7.5 mA
30 mV
5 mA
40 mV
3.75 mA
75 mV
2 mA
150 mV
1 mA
Temperature Coefficient
5
:
Voltage (0.02%/
C of Vmax)
Current (0.03%/
C of Imax)
1 mV/
C
22.5mA/
C
1.6 mV/
C
22.5mA/
C
2 mV/
C
18 mA/
C
4 mV/
C
9 mA/
C
8 mV/
C
4.5 mA/
C
12 mV/
C
3 mA/
C
16 mV/
C
2.25mA/
C
30 mV/
C
2 mA/
C
60 mV/
C
0.6mA/
C
Maximum Total Line Drop
with Remote Sensing
6
1V
1V
1V
2V
2V
2V
2V
2V
2V
Notes:
1
Warranted over a temperature range of 0–50
C, with remote sensing at output terminals.
2
AC input voltage variation within the allowed range, with constant load and temperature.
3
For 0–100% load variation, with constant nominal AC input voltage and temperature.
4
Maximum drift over 8 hours with constant line, load, temperature, after 30 min. warm–up.
5
Change in output per
C change in ambient temperature, with constant line and load.
6
Line drop subtracts from the maximum available output voltage at full rated power.
Table 1–1. DLM Series Specifications