beautypg.com

Standard discharge, (non-cooled kits only) – Vortech 2005-2008 Ford 4.0L V6 Mustang User Manual

Page 35

background image

P/N: 4FU020-610

©2008 Vortech Engineering, LLC

All Rights Reserved, Intl. Copr. Secured

06AUG08 v4.1 05MusV6(4FU..610v4.1)

25

1"ID HOSE CONNECTION

ON SUPERCHARGER

DISCHARGE ELBOW

15" x 1" HOSE

Ø

(TRIM TO FIT)

TO MANIFOLD PRESSURE/VACUUM

#16 HOSE CLAMPS

BYPASS

VALVE

TO INLET

DUCT

~6" X 1"

HOSE

Ø

8. STANDARD DISCHARGE, (Non-Cooled Kits Only)

A. Install the supplied supercharger elbow

between the supercharger discharge and the

throttle body. Secure with clamps. (See Fig.

8-a.)

B. Attach the bypass valve inlet to the discharge

elbow.

C. Attach one end of the supplied Ø1" hose to

the bypass valve discharge. Install and tight-

en the supplied #16 hose clamps on each

end of the bypass valve. The open end of the

hose will be connected to the air inlet in a

future step. (See Fig. 8-c)

D. Attach a length of 5/32" vacuum hose to the

bypass valve and route to the vacuum port

on top of the intake manifold. (See Fig. 8-c)

E. Remove the plastic union connecting the fuel

rail pressure sensor to the intake manifold.

Install the supplied TEE in its place. (See

Fig. 8-b.)

F. Attach the vacuum hose from the bypass

valve to the TEE.

Fig. 8-c

Fig. 8-a