beautypg.com

StorCase Technology FC-to-SCSI Single & Dual RAID User Manual

Page 43

background image

30

Configuration

StorCase Technology, Inc.

FC-SCSI Dual RAID Module User's Guide - Rev. A01

2.

Enter a name for the array and press Enter.
Up to 20 characters (any character, including spaces) can be used. If no name is to

be used, just press Enter (a name may be added or changed later).
The system will now ask if you want to create one partition for the entire array.

3.

Select Yes to create a single-partition array and press Enter (for creating multiple-

partition arrays, refer to section "Creating a Multiple-Partition Array" for further

information).
The LUN screen should now display (Figure 14).
The LUN displayed is the suggested default LUN assignment.

Figure 14: Array LUN Screen

4.

Select the LUN for the array and press Enter.
If the letters OV appear before a LUN, this indicates that the selection overlaps with

a soft LUN, most likely the controller or SAF-TE Environmental Processor (SEP) LUN.

An array at an overlapped LUN may be created, but it will not be seen by the host

system until the controller is rebooted.