StorCase Technology FC-to-SCSI Single & Dual RAID User Manual
Page 116

FC-SCSI Dual RAID Module User's Guide - Rev. A01
StorCase Technology, Inc.
Configuration
103
Table 8: Operating Mode Settings
Host Channel
Setting
Configuration
Description
Stand-Alone
Dual Port
Single RAID
Module Unit
Dual RAID
Module Unit
This option allows the controller to operate with two host ports. In
this mode, the same LUNs display on the two separate host ports.
Stand-Alone Dual Port mode allows the host to achieve greater
throughput by balancing I/O operations across the two host ports.
Host port fault tolerance is also achieved, since the host can con-
tinue accessing the controller if one host channel fails.
This option allows both controllers to operate independently and
in an active-active pair. Active-Active modes allow two controllers
to cooperate in system operation in a fault-tolerant manner. If one
controller fails while in Active-Active mode, the other controller
assumes its activities, allowing host access to continue.
When both controllers are online, each controller presents its
LUNs on only one port.
This option allows the use of just one controller, with the second
controller acting only as a backup (in case of a failure of the con-
troller in use).
When changing to this mode on one controller, both controllers
must be rebooted at the same time. Upon reboot, both controllers
will automatically be in Active-Passive Dual Port mode
Active-Active
Single Port
Active-Passive
Dual Port
Dual RAID
Module Unit
IFSII_FDR21
Dual RAID
Module Unit
Active-Active
Dual Port
This option allows both controllers to operate independently and
in an active-active pair. Active-Active modes allow two controllers
to cooperate in system operation in a fault-tolerant manner. If one
controller fails while in Active-Active mode, the other controller
assumes its activities, allowing host access to continue.
When both controllers are online, each controller presents its
LUNs on both ports, permitting redundant host access to all LUNs
when there is a failure between host and controller. After failover,
one port of the surviving controller presents Controller As LUNs
and other port presents Controller Bs LUNs.
When changing to this mode on one controller, both controllers
must be rebooted at the same time. Upon reboot, both controllers
will automatically be in Active-Active Dual Port mode