Disk channel errors – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual
Page 173

160
Appendix C - Troubleshooting
StorCase Technology, Inc.
FC-SCSI Dual RAID Module User's Guide - Rev. A01
Disk Channel Errors
Disk channel errors are similar to disk-detected errors, except they are detected by the
controller. Some disk channel errors are displayed as text strings, others are displayed as
hexadecimal codes. Most disk channel errors are informational, since the controller will issue
retries to correct any problem. Errors that cannot be corrected with retries will result in a critical
event describing the affected disk array.
Figure C-2 shows a typical disk channel error and accompanying hexadecimal code. Refer
to Table C-5 for disk channel error codes and their descriptions.
DISK CHANNEL ERR
1 : 0 0 Ts k Sta t : 3 1
IFS_63
Disk
Channel
SCSI ID
Error
Code
Figure C-2: Typical Disk Channel Error
Table C-4: ASC/ASCQ Codes and Descriptions
ASC
ASCQ
IFS_65
0C
0C
Description
Write error - auto reallocation failed
11
11
11
11
11
11
11
47
48
02
03
00
01
02
03
04
0B
0C
00
00
Write error - recommend reassignment
Unrecovered read error
Read retries exhausted
Error too long to correct
Multiple read errors
Unrecovered read error - recommend reassignment
Unrecovered read error - recommend rewrite the data
SCSI parity error
Initiator detected error message received
Unrecovered read error - auto reallocate failed