beautypg.com

Working with the operating modes – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual

Page 113

background image

100

Configuration

StorCase Technology, Inc.

FC-SCSI Dual RAID Module User's Guide - Rev. A01

6.

Select the desired Initiator ID and press Enter.
StorCase does not recommend changing the factory default Initiator ID(s).
If in Active-Active mode, the Initiator ID cannot be changed.
The system will confirm the new Initiator ID.

7.

Select Yes and press Enter.

8.

Press Esc to return to the Configuration Menu.

Working with the Operating Modes

NOTES: Default operating mode for the Dual RAID Controller Module unit is Active-Passive.

Default operating mode for the Single RAID Controller Module unit is Stand-Alone

Dual Port.
Default operating mode for the Single RAID Controller Module upgrade is Stand-Alone

Dual Port.
If upgrading a Single RAID Controller Module unit with the Single RAID Controller

Module upgrade (to a Dual RAID Controller Module configuration), make sure to

reconfigure the operating mode accordingly.

The Dual RAID Controller Module unit can operate in the following modes: Stand-Alone Single

Port, Stand-Alone Dual Port, Active-Active Single Port, Active-Active Dual Port, and Active-

Passive Dual Port.
In Active-Active configurations, two controller modules operate as a pair. If one controller fails,

the other can take over for the failed controller module.