Working with the operating modes – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual
Page 113

100
Configuration
StorCase Technology, Inc.
FC-SCSI Dual RAID Module User's Guide - Rev. A01
6.
Select the desired Initiator ID and press Enter.
StorCase does not recommend changing the factory default Initiator ID(s).
If in Active-Active mode, the Initiator ID cannot be changed.
The system will confirm the new Initiator ID.
7.
Select Yes and press Enter.
8.
Press Esc to return to the Configuration Menu.
Working with the Operating Modes
NOTES: Default operating mode for the Dual RAID Controller Module unit is Active-Passive.
Default operating mode for the Single RAID Controller Module unit is Stand-Alone
Dual Port.
Default operating mode for the Single RAID Controller Module upgrade is Stand-Alone
Dual Port.
If upgrading a Single RAID Controller Module unit with the Single RAID Controller
Module upgrade (to a Dual RAID Controller Module configuration), make sure to
reconfigure the operating mode accordingly.
The Dual RAID Controller Module unit can operate in the following modes: Stand-Alone Single
Port, Stand-Alone Dual Port, Active-Active Single Port, Active-Active Dual Port, and Active-
Passive Dual Port.
In Active-Active configurations, two controller modules operate as a pair. If one controller fails,
the other can take over for the failed controller module.