FC-SCSI Dual RAID Module User's Guide - Rev. A01

StorCase Technology, Inc.

Configuration

23

InfoStation Serial Port Set-Up

To access the Administrator Utility via the UI Module RS-232 serial port, the user must first

configure the Serial Port Set-Up in the UI Module (see below).
Refer to the InfoStation User's Guide (specifically, sections "InfoStation User Interface" and

"Serial Port Set-Up") for further information.
NOTES:

Press CANCEL at anytime to exit the menu system and return to the Default

Display. The menu system will automatically cancel after 15 seconds of

User inactivity.

Factory default is S.Port0.

The following lists each InfoStation serial port option and its description.

S.Port0 =

InfoMon monitoring via the UI Module Serial Port (refer to the InfoMon User's

Guide for further information).

S.Port1 =

RAID configuration through the Primary RAID Controller Module via the

UI Module Serial Port.

S.Port2 =

RAID configuration through the Secondary RAID Controller Module via the

UI Module Serial Port.

1.

Press ENTER at the Default Display so that

display = Status.

2.

Press DOWN until display = Setup.

3.

Press ENTER so that display = Enc. ID.

4.

Press DOWN until display = Ser.Port

5.

Press ENTER so that display = S-Portx .

This is the current serial port set-up.

6.

Press UP or DOWN to change the serial port

option.

7.

Press ENTER to accept the change.

ENTER

S t a t u s

S e t u p

T E M P : x x C

E n c . I D

ENTER

DOWN

ENTER

DOWN

S e r . P o r t

S - P o r t = 0

UP/DOWN

ENTER

S - P o r t = 1

S - P o r t = 1