beautypg.com

Infostation fibre channel speed set-up – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual

Page 37

background image

24

Configuration

StorCase Technology, Inc.

FC-SCSI Dual RAID Module User's Guide - Rev. A01

S.Port3 =

RAID configuration through the Primary RAID Controller Module via the

RAID Controller Module Serial Port.

InfoMon can also be monitored simultaneously via the UI Module Serial Port.

S.Port4 =

RAID configuration through the Secondary RAID Controller Module via the

RAID Controller Module Serial Port.

InfoMon can also be monitored simultaneously via the UI Module Serial Port.

InfoStation Fibre Channel Speed Set-Up

The following steps show how to change the InfoStation Fibre Channel Speed. Refer to the

InfoStation User's Guide (specifically, sections "InfoStation User Interface" and "Fibre

Channel Speed Set-Up") for further information.

Fibre Channel speed must also be set in the RAID Controller and FC HBA (refer to section

"Configuring the Host Channels" and FC HBA documentation for further information).

NOTES:

Press CANCEL at anytime to exit the menu system and return to the Default

Display. The menu system will automatically cancel after 15 seconds of

User inactivity.

FC Speed 0 = 1Gbps

FC Speed 1 = 2Gbps (Factory Default)

ENTER

S t a t u s

S e t u p

T E M P : x x C

E n c . I D

ENTER

DOWN

ENTER

DOWN

F C S p e e d

UP/DOWN

F C S P D = 0

F C S P D = 1

F C S P D = 0

ENTER

1.

Press ENTER at the Default Display so that

display = Status.

2.

Press DOWN until display = Setup.

3.

Press ENTER so that display = Enc. ID.

4.

Press DOWN until display = FC Speed.

5.

Press ENTER so that display = FC SPD=1.

This is the current Fibre Channel speed.

6.

Press UP or DOWN to change the Fibre Channel

speed.

7.

Press ENTER to accept the change.