Infostation fibre channel speed set-up – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual
Page 37

24
Configuration
StorCase Technology, Inc.
FC-SCSI Dual RAID Module User's Guide - Rev. A01
S.Port3 =
RAID configuration through the Primary RAID Controller Module via the
RAID Controller Module Serial Port.
InfoMon can also be monitored simultaneously via the UI Module Serial Port.
S.Port4 =
RAID configuration through the Secondary RAID Controller Module via the
RAID Controller Module Serial Port.
InfoMon can also be monitored simultaneously via the UI Module Serial Port.
InfoStation Fibre Channel Speed Set-Up
The following steps show how to change the InfoStation Fibre Channel Speed. Refer to the
InfoStation User's Guide (specifically, sections "InfoStation User Interface" and "Fibre
Channel Speed Set-Up") for further information.
Fibre Channel speed must also be set in the RAID Controller and FC HBA (refer to section
"Configuring the Host Channels" and FC HBA documentation for further information).
NOTES:
Press CANCEL at anytime to exit the menu system and return to the Default
Display. The menu system will automatically cancel after 15 seconds of
User inactivity.
FC Speed 0 = 1Gbps
FC Speed 1 = 2Gbps (Factory Default)
ENTER
S t a t u s
S e t u p
T E M P : x x C
E n c . I D
ENTER
DOWN
ENTER
DOWN
F C S p e e d
UP/DOWN
F C S P D = 0
F C S P D = 1
F C S P D = 0
ENTER
1.
Press ENTER at the Default Display so that
display = Status.
2.
Press DOWN until display = Setup.
3.
Press ENTER so that display = Enc. ID.
4.
Press DOWN until display = FC Speed.
5.
Press ENTER so that display = FC SPD=1.
This is the current Fibre Channel speed.
6.
Press UP or DOWN to change the Fibre Channel
speed.
7.
Press ENTER to accept the change.