Changing the alarm mute setting – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual

Page 123

background image

110

Configuration

StorCase Technology, Inc.

FC-SCSI Dual RAID Module User's Guide - Rev. A01

Table 9: Alarm Thresholds and Procedures

To enable/disable the alarm:

1.

Select Configuration Menu from the System Menu and press Enter.
The Configuration Menu should now display (Figure 31).

2.

Select Alarm Mute and press Enter.
The Alarm Mute screen will display (Figure 65).
The current setting is marked with an * next to it.

Changing the Alarm Mute Setting

This function allows the user to enable/disable the audible alarm. Changing the mute setting

allows the user to turn OFF the alarm (the alarm should be turned back ON once the problem

is resolved).
Alarm conditions will trigger event messages that display in the Disk Array Administrator Utility

and in the event log (refer to section "Displaying the Event Log" for further information).

Alarm Threshold

Procedures

IFSII_DR16

VCC Voltage

Shutdown: 5V -6.5% and +10%

12V Voltage

Shutdown: 12V -10% and +10%

Onboard Temperature

Warning: 0 C - 5 C and

45 C - 50 C

Shutdown: < 0 C

> 50 C

Check the Disk Array Administrator Utility for more details (refer to section

“Accessing the Disk Array Administrator Utility”).

CPU Temperature

Warning: 0 C - 5 C and

65 C - 70 C

Shutdown: < 0 C

> 70 C

Check the ambient temperature and lower the threshold (if necessary).

Ambient temperature should be less than 45 C.

Check the Disk Array Administrator Utility for more details (refer to section

“Accessing the Disk Array Administrator Utility”).

Check the Disk Array Administrator Utility to for more details (refer to section

“Accessing the Disk Array Administrator Utility”).

Check the Disk Array Administrator Utility for more details (refer to

section “Accessing the Disk Array Administrator Utility”).

For shutdown events, turn OFF power to the controller and send it in for

servicing