Configuration, Configuration overview, Starting the administrator utility – StorCase Technology FC-to-SCSI Single & Dual RAID User Manual
Page 35

22
Configuration
StorCase Technology, Inc.
FC-SCSI Dual RAID Module User's Guide - Rev. A01
CONFIGURATION
Configuration Overview
To configure the FC-to-SCSI Dual RAID Controller Module unit, run the Administrator Utility via
a computer serial port (cable provided). This utility allows the user to:
Create arrays
Delete arrays
Monitor array statistics
Verify array integrity
Change array configurations
Monitor drive failures and use spare drives
Monitor controller environmental, configuration, and status information
Starting the Administrator Utility
NOTES: Microsoft
®
Windows
®
3.x and Windows
®
NT 3.5x include a program called Terminal
which does not support ANSI color. If using either O/S, select VT-100 for terminal
emulation or use a third-party software program such as Procomm for Windows.
Microsoft
®
Windows
®
95/98/NT/2000 includes a program called HyperTerminal that
supports ANSI color.
FC-to-SCSI RAID Controller Module will only work with InfoStation UI F/W Rev. 2.0.11
or higher.
The Administrator Utility is implemented with a VT-100 or ANSI terminal connected through the
RS-232 serial port on the Dual RAID Controller Module unit (Figure 2A). This utility is embedded
in the firmware; software loading is not required unless for upgrade purposes.
The Administrator Utility can also be implemented through the RS-232 serial port on the
InfoStation User Interface Module, as shown in Figure 10. This is especially convenient in rack-
mount environments where it may be difficult to access the Dual RAID Controller Module unit
directly.
RS-232
Serial Port
IFS_6a
Figure 10: InfoStation User Interface Module