Changing the Additional SAF-TE Board Settings
The user can change four (4) additional settings:
Polling Interval - The interval (in seconds) that the controller polls the SAF-TE Board
for status changes (default is 5 seconds).
Temperature Sensor Status - This controls whether the controller's onboard
temperature sensor provides temperature information to the host along with the en-
closure's temperature detected by the SAF-TE Board. Default is OFF (neither the
controller nor the enclosure is providing temperature information to the host).
Slot Update Status (Slot Flags) - This controls whether the controller sends com-
mands to the SAF-TE Board to upbeat the status of each enclosure drive bay. Default
is ON (controller will request status updates from the enclosure).
Enclosure Update Status (Global Flags)- This controls whether the controller
will send commands to the SAF-TE Board to update the overall status of the enclo-
sure. Default setting is OFF (controller will not request status updates from the
enclosure).
To change the SEP Settings:
1.
Select Configuration Menu from the System Menu and press Enter.
The Configuration Menu should now display (Figure 31).
2.
Select SEP Configuration and press Enter.
The SEP Configuration screen should now display (Figure 80).
3.
Select SEP Settings and press Enter.
The Poll Rate screen should now display (Figure 83).
The system will confirm your request to change the LUN.
6.
Select Yes and press Enter.
To
Do This
Not assign the
SEP a LUN
Keep the same LUN
for the SEP at all times
Select NONE and
press Enter.
Select the [LUN] you want
to use and press Enter.
This can be any number 0-63 that
is not already in use.