LINK Systems OmniLink 5000 User Manual
Page 38
4.20
From the Jobs Menu, Figure 4.10, depressing the ERASE SETUP softkey will transfer the screen to the
Select Job menu. The Select Job menu allows the user to select the job that is to be erased. The
user must have access control to perform a job erase. Access control is described in Section 3. If the user
obtains access control by using the password system, the user must be configured to have access to erase jobs
from memory.
The method for locating a job is the same as those for recalling one. Once the job to be erased has been
located, the ERASE SETUP softkey can be used to erase the job.
Section 4.6 Counters
From the Main Menu, Figure 4.1, depressing the COUNTER softkey displays the menu shown in Figure 4.14
and provides the operator certain production information. The present quantities of the order counter, batch
counter, quality counter, auxiliary counters, scrap counter, and stoke counter can be viewed. In order to
make any changes to the counters, the operator must obtain control access. Access control is described in
Section 3.
Stroke
Mode Single Stroke
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
PC STATUS
1000
LIMIT
SWITCH
EXIT
0
0
Program/Run Switch
TOP
CHANGE
COUNT
CHANGE
LIMIT
DECREMENT
COUNT
COUNTER
OFF
RESET
COUNTER
DECREMENT
SCRAP
INCREMENT
SCRAP
CONFIG
COUNTER
Job Number
Job Description
1
FRONT BRACKET
Present Running Status
Program/Run Switch
COUNTER NAME
COUNT
LIMIT
STATE
PERCENT COMPLETE
Order Count
Batch Count
Quality Count
Aux 1 Count
Aux 2 Count
Aux 3 Count
Aux 4 Count
Aux 5 Count
Aux 6 Count
Aux 7 Count
Stroke Count
978776
1000
50
90
50
0
0
0
0
0
0
2000
200
100
50
0
0
0
0
0
0
ON
ON
OFF
TRIP
OFF
OFF
OFF
OFF
OFF
OFF
50%
25%
90%
100%
Scrap Count 4 Scrap Rate 0.3984%
1
2
3
4
5
CHANGE
SCRAP
INCREMENT
COUNT
ADD
TO SCRAP
DECREMENT
COUNT
SUBTRACT
FROM SCRAP
Figure 4.14 Counter Menu
The display provides the following information:
1.
The current Job Number and Description
2.
Present running status of the press control
3.
Current Count, Limit, State, and Percent Complete of the Order, Batch, Quality, and all Auxiliary
Counters. These are called Production Counters.
4.
Current Stroke Count