3.4
19
PLC Screen 1 Sets
Change parameters on Screen 1 of the Programmable
Logic Controller Interface
20
PLC Screen 2 Sets
Change parameters on Screen 2 of the Programmable
Logic Controller Interface
21
PLC Screen 3 Sets
Change parameters on Screen 3 of the Programmable
Logic Controller Interface
22
PLC Screen 4 Sets
Change parameters on Screen 4 of the Programmable
Logic Controller Interface
23
Special Interface
Change parameters on the Special Interface Screen
24
Auto SS/COD Time
Change the Automatic Single Stroke maximum time
between strokes, the Continuous on Demand maximum
time between Run cycles, and the Feed Complete Angle
25
Reset Brake Monitor
Reset Brake Monitor faults
26
Motor Speed Adjust
Adjust motor speed
27
Store Jobs
Store jobs in memory, edit Machine Notes and Job
Notes
28
Recall Jobs
Recall jobs from memory
29
Erase Jobs
Erase jobs in memory
30
Reserved for future use
31
Reserved for future use
32
Reserved for future use
Section 3.3 Access Control Operation
To gain access control the user must use one of two means or a combination of these two means. These
means are the Program/Run key or the user password system.
Section 3.3.1 Program/Run Key Switch Operation
The Program/Run key switch is located on the lower right side of the operator terminal. This is a two
position switch. The key is removable in the RUN position only. If the Program/Run key switch is being
used as a means to access the restricted items, the switch must be turned to the PROG position. When the
Program/Run key switch is switched to the PROG position, the press will Top Stop and stroking will be
prohibited until the switch is returned to the RUN position.
When operating in the Key Only mode the key switch is the only means available to access the restricted