LINK Systems OmniLink 5000 User Manual
Page 19
4.1
Section 4 Operating Menus
Section 4.1 Main Menu
Figure 4.1 shows the Main Operating Menu. This screen provides an overall view of the functions available
along with pertinent information for each. From this menu the operator may select the Press Control,
Programmable Limit Switch, Automatic Setups (with optional board installed), Tonnage Monitor (with
optional board installed), Die Protection (with optional board installed), Job Setups, Counters, and Motor
Speed Adjust. By depressing the adjacent softkey, the screen will transfer to the Press Control, Automatic
Setups, Tonnage Monitor, Die Protection, Programmable Limit Switch, Counters, or Motor Speed screens.
Stroke
Mode Single Stroke
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
PC STATUS
Counter OFF
MAIN
SCREEN
PRESS
CONTROL
AUTO
SETS
TONNAGE
MONITOR
DIE
PROTECTION
LIMIT
SWITCH
JOB
SETUPS
0
0
MOTOR
SPEED
STATUS:
READY TO RUN
STATUS:
ALL CONDITIONS OKAY
STATUS:
ALL CONDITIONS OKAY
STATUS:
ALL CONDITIONS OKAY
JOB NUMBER DESCRIPTION
100000 FRONT BRACKET
COUNTER LIMIT QUANTITY STATE
ORDER
BATCH
SPM
0
% LOAD
161
2000
500
7
7
ON
ON
READY TO STROKE
TOP
COUNTERS
6 5 4 3 2 1
7
8
Figure 4.1 Main Menu
The display provides the following information:
1.
The present running status of the press control.
2.
The current status of the automatic slide adjust and air adjust module, if this module is installed.
3.
The present status of the tonnage monitor module, if this module is installed. This includes setpoint
alarms, faults, or a bypass condition.
4.
The present status of the die protection module, if this module is installed. This includes a top stop
or emergency stop due to sensor inputs, faults, or a bypassed condition.
5.
The present Job Number and its description.