background image

PE Series Operator’s Manual

B-5

Barcode Fonts

Font

Bar Code

Length

Cksum

Valid Characters

A

Code 3 of 9

Varies

No

0-9, A-Z, -. *$/+% and space char.

B

UPC-A

11 digits

Yes

0-9

C

UPC-E

6 digits

Yes

0-9

D

Interleaved 2 of 5

Varies

No

0-9

E

Code 128
(A,B,C)

Varies

M-103

entire 128 ASCII character set.

F

EAN-13

12 digits

Yes

0-9

G

EAN-8

7 digits

Yes

0-9

H

Health Industry
Bar Code
(HIBC)

Varies

M-43

0-9, A-Z, -$:/. The Host must
supply leading "+"'s

I

Codabar

Varies
(Min. 3)

No

0-9, -, ., $, :, /, +, and the start/stop
codes: a, b, c, and d.

J

Interleaved 2 of 5
with modulo 10
checksum

Varies

M-10

0-9

K

Plessey

Varies

M-10

0-9. Option + is last character for
second M-11 checksum

L

Interleaved 2 of 5
with modulo 10
checksum &
shipping bearer
bars

13

M-10

0-9

M

UPC 2 digit add.

2 digits

Yes

0-9

N

UPC 5 digit add.

5 digits

Yes

0-9

O

Code 93

Varies

No

All 128 ASCII characters

p

Postnet

Varies

Yes

0-9

Q

UCC/EAN Code
128

19 digits

Yes

0-9

R

UCC/EAN Code
128 K-MART
NON EDI

18 digits

Yes

0-9

S

UCC/EAN Code
128 Random
Weight

Varies.
At least
34 digits

Yes

0-9

T

Telepen

Varies

Yes

All 128 ASCII characters

u

UPS MaxiCode

84

Yes

0-9, A-Z

v

FIM

1 char.

No

A, B, C, or D

z

PDF-417

Varies

Yes

All ASCII characters

Table B-3 Valid Bar Code Font ASCII Characters