Barcode fonts – Datamax PE User Manual
Page 79
PE Series Operator’s Manual
B-5
Barcode Fonts
Font
Bar Code
Length
Cksum
Valid Characters
A
Code 3 of 9
Varies
No
0-9, A-Z, -. *$/+% and space char.
B
UPC-A
11 digits
Yes
0-9
C
UPC-E
6 digits
Yes
0-9
D
Interleaved 2 of 5
Varies
No
0-9
E
Code 128
(A,B,C)
Varies
M-103
entire 128 ASCII character set.
F
EAN-13
12 digits
Yes
0-9
G
EAN-8
7 digits
Yes
0-9
H
Health Industry
Bar Code
(HIBC)
Varies
M-43
0-9, A-Z, -$:/. The Host must
supply leading "+"'s
I
Codabar
Varies
(Min. 3)
No
0-9, -, ., $, :, /, +, and the start/stop
codes: a, b, c, and d.
J
Interleaved 2 of 5
with modulo 10
checksum
Varies
M-10
0-9
K
Plessey
Varies
M-10
0-9. Option + is last character for
second M-11 checksum
L
Interleaved 2 of 5
with modulo 10
checksum &
shipping bearer
bars
13
M-10
0-9
M
UPC 2 digit add.
2 digits
Yes
0-9
N
UPC 5 digit add.
5 digits
Yes
0-9
O
Code 93
Varies
No
All 128 ASCII characters
p
Postnet
Varies
Yes
0-9
Q
UCC/EAN Code
128
19 digits
Yes
0-9
R
UCC/EAN Code
128 K-MART
NON EDI
18 digits
Yes
0-9
S
UCC/EAN Code
128 Random
Weight
Varies.
At least
34 digits
Yes
0-9
T
Telepen
Varies
Yes
All 128 ASCII characters
u
UPS MaxiCode
84
Yes
0-9, A-Z
v
FIM
1 char.
No
A, B, C, or D
z
PDF-417
Varies
Yes
All ASCII characters
Table B-3 Valid Bar Code Font ASCII Characters