beautypg.com

Datamax PE User Manual

Page 49

background image

PE Series Operator’s Manual

39

Nbjoufobodf

(cont.)

Installed Options

There are two installed options to choose from:

Cutter
Ribbon Saver

Npevmft

Modules contain a set of five memory function

routines. Some of these memory tests are
destructive, in this case, the printer will prompt “Are
you sure?” before beginning.

Print Directory

Prints a list of all files (fonts, images and labels),

stored on the selected module.

Module A

Module A is the printer's internal memory allocation.

Module B

Module B refers to an external Flash, if equipped.

Print File

Prints a file from a selected module.

Print File on

Module A

Prints from Module A; specify file type and then file

name. The printer will then print the contents.

Print File on

Module B

Same function as Module A, but prints the specified

contents of the external module file.

Copy Module

Copies data from one module to another.

Copy From

Module A

Copies from Module A to Module B.

Copy From

Module B

Copies from Module B to Module A.

Format Module

Formats a selected memory module.

Caution! Formatting permanently erases data!

Format Module A

Formats Module A. Printer will prompt, “Are You

Sure?” All data will be lost.

Format Module B

Same as Module A. The Write Protect Switch must

be turned ‘Off’ to format this module.

Test Module

Tests the selected memory module by writing to,

reading from and then verifying the data for accuracy.

Caution! Testing permanently erases data!

Test Module A

Tests Module A. The printer will prompt, “Are You

Sure?” All data will be lost.

Test Module B

Same as Module A. The Write Protect Switch must

be turned ‘Off’ to test this module.