4.1.2 Advanced Setup
Advanced setup is a gateway leading to additional system, maintenance
and testing sub-levels.
PE Options
System Options
Low Ribbon Diameter
Compatibility
Printer Model
Operation
Counters
Communications
Date/Time
Maintenance
Label Options
Modules
LCD :
CBTJD!!!GVODUJPO
BEWBODFE!!TFUVQ
From Basic Function/Advanced Setup, enter by pressing the Ø key:
QF!Pqujpot
Three selections used to integrate functions with an
applicator.
PE Output Signal
Selects the type of status signal used between the
printer and applicator port pin #6.
*Low Pulse
High to low signals end of print cycle.
High Pulse
Low to high signals end of print cycle.
Low Status
Steady low signal during printing.
High Status
Steady high signal during printing.
Disable
No print and apply function.