beautypg.com

Datamax PE User Manual

Page 46

background image

PE Series Operator’s Manual

36

Dpnqbubcjmjuz

Three selections to control label positioning

Offset Bias
*220
110

Selects from two different Start of Print positions.

This command sets the point where printing starts,
relative to the Top-of-Form Adjust value. The
printer will feed from the Offset Bias and the Top-
of-Form Adjust value to begin printing.

Positioning
(PE 42 only)

Allows the selection of the column position

calculation based upon one of two different values.

*203 dpi

Exact column positioning.

200 dpi

Host CMDS-Ignore

This parameter instructs the firmware whether to

process the DPL commands for Offset Position
(O), Peel Possition (f), and the Heat value
(stx>l>h)

ProdigyPlus Mode

This function sets the parameters so the printer will

emulate a Prodigy Plus printer. These parameters
are:

Offset Bias = 110
Positioning = 200DPI
Host Positioning = IGNORE
Conversion = Inches
Peel Position = .25" (1" if cutter is installed)

Pqfsbujpo

Sets three different operational functions.

Pause Mode

Causes the printer to pause between printing each

label.

*Disable
Enabled

The ‘Pause’ button must be pushed in order to print

the next label.

Feedback Mode

Causes the printer to feedback ASCII characters 30

and 31.

*Disable
Enable

The printer will return a 30 after each label is

printed and a 31 after each batch of labels.