(for more details see Section 3.1 and Appendix 3):
Work day

The number of consecutive workdays.

Program Number

Reflects the selected program (can be selected only inside panel C 03). See
Section 5.2.

Rest day

The number of consecutive rest days.

Weekday

Week-day labels.

Workday

Use the yes or no indication (on the keypad) below each weekday label to
indicate specific workdays for the indexed program.

5.7.3 SET PRIORITY – S 33

Prog 07

Priority 04

Sectors/Group 08

SET PRIORITY S33

This panel allows the setting of priority level for each program. Programs can
share the same priority level. When a conflict occurs between two programs with
the same priority, the program that has the earliest starting time will be executed
first. The program number indexes this panel (For more details see Section 3.1
and appendix 3). This panel displays and allows the setting of the following
parameters:
Program Number

Reflects the selected program (can be selected only inside panel C 03). See

Section 5.2.

Priority

The priority level. This number can be set from 1 to 5, where 5 is the highest
priority.

Sectors / Group

The number of sectors/groups for the indexed program is the maximum
number of valves that will be opened simultaneously.