and is not program specific.
S in = Real time value of EC input sensor. This is an option sensor input to
measure the conductivity of the incoming water supply. This reading applies to
the entire process and is not program specific.
System clock

5.2.4 SOLAR RAD IRRIG – C 06

Prog 08

Irrig=0720Wh/m2

Acc=0720Wh/m2 13:15

SOLAR RAD IRRIG C06

This panel displays the solar radiation irrigation settings. Due to the effects of
solar radiation it may be necessary to augment (correct) the irrigation process
accordingly. The program number indexes this panel. This panel contains the
following information:
Program Number

Reflects the selected program (can be selected only inside panel C 03). See
Section 5.2.

Irrig = The set level of accumulated solar radiation used for irrigation correc-
tion. This is a set point. Radiation beyond this limit will trigger a correction to the
irrigation process.
Acc = Real time value of accumulated solar radiation.
System clock

5.2.5 WORK TIME COND – C 08

Prog 08 Time Y

Day Y

Period Y 13:15

WORK TIME COND C08

The program number indexes this panel. This panel contains the following infor-
mation:
Program Number

Reflects the selected program (can be selected only inside panel C 03). See
Section 5.2.

Time

Indicates if the selected program is set to run on a time schedule.