Hanna Instruments HI 99181 User Manual
Instruction manual
w w w . h a n n a i n s t . c o m
Range
-2.00 to 16.00 pH
-5.0 to 105.0°C / 23.0 to 221.0°F
Resolution
0.01 pH / 0.1°C / 0.1°F
Accuracy
±0.02 pH
(@20°C/68°F)
±0.5°C up to 60°C; ±1.0°C outside
±1.0°F up to 140°F; ±2.0°F outside
Typical EMC
±0.02 pH
Deviation
±0.2°C or ±0.4°F
Temperature Compensation
Automatic
pH Calibration
Automatic, 1 or 2 point
choose between 2 sets of buffers
(standard: 4.01/7.01/10.01 or NIST: 4.01/6.86/9.18)
Probe (included)
HI 1414D/50
preamplified pH/temperature probe
Battery Type
3 x 1.5V AAA
Battery Life
Approximately 1200 hours of continuous use
Instruction Manual
HI 99181
Portable Waterproof
Skin pH Meter
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the
instrument. If you need additional technical information, do not
hesitate to e-mail us at
All Hanna Instruments meters are warranted for two years
against defects in workmanship and materials when used for
their intended purpose and maintained according to instructions.
The probes are warranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damage due to accidents, misuse, tampering or lack of
prescribed maintenance are not covered.
If service is required, contact the dealer from whom you
purchased the instrument. If under warranty, report the model
number, date of purchase, serial number and the nature of the
problem. If the repair is not covered by the warranty, you will
be notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods
Authorization Number from the Customer Service department
and then send it with shipment costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete
protection.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner.
Remove the instrument from the packing material and examine
it carefully to make sure that no damage has occurred during
shipment. If noticeable damage is evident, notify your dealer.
Note: Save all packing material until you are sure that the
instrument functions correctly. All defective items must be
returned in the original packing together with the
supplied accessories.
HI 99181 is a portable, microprocessor-based pH and
temperature meter with a special flat surface probe.
The
HI 1414D/50 probe has been specially designed with a flat
tip for skin pH measurement.
Moreover, a built-in temperature sensor allows simultaneous
temperature compensated pH and temperature readings and
an integral pH sensor preamplifier provide measurements
impervious to noise and electrical interferences.
The meter is supplied with:
•
HI 1414D/50 pH/temperature probe with flat tip,
50 mm-long body, DIN connector and 1m (3.3’) cable
•
HI 700621 Cleaning solution for skin grease and sebum,
20 mL sachet (2 pcs.)
• Calibration and cleaning solution sachets
• 3 x 1.5V AAA batteries
• Instruction manual.
Hanna Instruments reserves the right to modify the design,
construction and appearance of its products without advance
notice.
HI 1414D/50 Preamplified pH probe with flat-tip 50 mm-long
body, built-in temperature sensor, DIN connector
and 1 m (3.3’) cable
HI 70004P
pH 4.01 buffer solution, 20 mL sachet (25 pcs.)
HI 7004L
pH 4.01 buffer solution, 500 mL bottle
HI 70006P
pH 6.86 buffer solution, 20 mL sachet (25 pcs.)
HI 7006L
pH 6.86 buffer solution, 500 mL bottle
HI 70007P
pH 7.01 buffer solution, 20 mL sachet (25 pcs.)
HI 7007L
pH 7.01 buffer solution, 500 mL bottle
HI 70300M
pH electrode Storage solution, 230 mL bottle
HI 70300L
pH electrode Storage solution, 500 mL bottle
HI 7061M
pH electrode General purpose cleaning solution,
230 mL bottle
HI 7061L
pH electrode Cleaning solution, 500 mL bottle
HI 700620P Cleaning & disinfection solution for removal of
skin residuals, 20 mL sachet (25 pcs.)
HI 70620M
Cleaning & disinfection solution for removal of
skin residuals, 230 mL bottle
HI 70620L
Cleaning & disinfection solution for removal of
skin residuals, 500 mL bottle
HI 700621P Cleaning solution for removal of skin grease and
sebum, 20 mL sachet (25 pcs.)
HI 70621M
Cleaning solution for removal of skin grease and
sebum, 230 mL bottle
HI 70621L
Cleaning solution for removal of skin grease and
sebum, 500 mL bottle
HI 70960
Electrolyte solution for sample preparation,
30 mL bottle
HI 76405
Electrode holder
1. Automatic Temperature Compensation indicator
2. Battery percentage (visible at power up)
3. Secondary display
4. Low battery indicator
5. Stability indicator
6. pH calibration indicator
7. Selectable temperature unit
8. Primary display
9. Measuring unit for primary display
IST99181Z 01/11
Auto-off
After 8 minutes of non-use
Environment
0 to 50°C (32 to 122°F); RH max. 100%
Dimensions
152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight
205 g (7.2 oz.)
WARRANTY
GENERAL DESCRIPTION
SPECIFICATIONS
PRELIMINARY EXAMINATION
LCD DESCRIPTION
ACCESSORIES