Hanna Instruments HI 8000 Series User Manual
Page 36

36
5.3.5 PROGRAM AVERAGES – C 23
From: 09-26 13:37;12
05.3pH Prog 01
06.7mS 13:15
PROGRAM AVERAGES C23
This panel provides a pH & EC average for each of the irrigation programs. The
program number indexes this panel. This panel contains the following informa-
tion:
From
Time stamp indicating the start of recording (statistics).
pH
The pH average for the indexed program.
Program Number
Reflects the selected program (can be selected only inside panel C 03). See
Section 5.2.
mS
The EC average for the indexed program.
System clock
5.3.6 SECTOR AVERAGES – C 24
From: 09-26 13:37;12
05.3pH Sect 01/01
06.7mS 13:15
SECTOR AVERAGES C24
This panel provides an average pH and EC reading for each of the irrigation
sectors. The valve number indexes this panel. This panel contains the following
information:
From
Time stamp indicating the start of recording (statistics).
pH
The average pH reading for the indexed valve.
Sect
The sector number (label) / valve number (index for this panel).
mS
The average EC reading for the indexed valve.
System clock