beautypg.com

Table 8d — superheat charging table, 48sx042 – Carrier 48SX024-048 User Manual

Page 35

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Table 8C — Superheat Charging Table, 48SX036

TEMP (F)

AIR ENT

EVAP AIR - CFM

1200

Evap Air — Ewb (F

54

56

58

60

62

64

66

68

70

72

74

76

65

SPH

21.3

21.3

21 3

21.3

22.0

22.6

23.3

23 5

23.7

23.8

23.3

22 8

70

SPH

19.3

19.3

193

193

20.2

21 2

22 2

22.3

22 5

22.6

22.0

21.5

75

SPH

17.2

172

17.2

17.2

18.5

197

21 0

21 1

21.3

21.4

20.7

20 1

80

SPH

13.6

13.6

13.6

13.6

15.1

166

18.0

18.5

18.9

19.3

19.4

19.5

85

SPH

10.1

10 1

10 1

10.1

11.7

134

15 0

15.8

165

173

18.1

19.0

90

SPH

6.5

6.5

6.5

6.5

8.8

11.2

135

14.6

157

168

17.2

17.6

95

SPH

*

*

*

*

60

90

120

13.4

148

162

16.2

16.2

100

SPH

*

*

*

*

*

*

60

8.7

11 4

14 1

14.9

15.6

105

SPH

*

*

*

*

*

*

8.0

12 1

13.6

15.1

110

SPH

*

*

*

*

*

*

‘k

*

10.0

11.5

13.0

115

SPH

*

*

*

*

*

*

*

*

*

8.0

9.5

11.0

LEGEND

Ewb — Entering Wet Bulb
SPH — Superheat at Compressor (F)

*Do not attempt to charge system under these conditions — refrig­

erant slugging may occur

Table 8D — Superheat Charging Table, 48SX042

TEMP (F)

AIR ENT

EVAP AIR - CFM

1400

Evap Air — Ewb (F)

54

56

58

60

62

64

66

68

70

72

74

76

65

SPH

23 9

23 9

23.9

23.9

24.4

24 9

25 5

25 8

26.1

26 5

25.6

24 7

70

SPH

21.9

21.9

21 9

21.9

22.4

22 9

23 4

23 7

24.1

24 5

24 0

23.5

75

SPH

198

19.8

198

19.8

20 3

20 8

21 3

21 7

22 0

22 4

22.4

22 4

80

SPH

16.3

163

16.3

163

17.9

19.6

21.3

21 5

21.7

21.8

21 8

21 8

85

SPH

12 7

12.7

127

12 7

15.6

18.4

21 3

21 3

21.3

21 3

21 3

21 3

90

SPH

9.2

9.2

92

9.2

12.0

14 9

178

187

19.7

20.8

20.8

20 8

95

SPH

56

5.6

5.6

56

8.5

11.3

14.2

16.2

182

20.2

20.2

20 2

100

SPH

*

*

*

*

k

80

106

13 1

156

18.1

18.9

19.6

105

SPH

*

*

*

*

k

*

7 1

10 1

13.1

16.1

17.6

19 1

110

SPH

*

k

*

k

k

k

k

70

105

14.0

15.5

170

115

SPH

*

k

*

*

*

*

*

k

8.0

12.0

13.5

15.0

LEGEND

Ewb — Entering Wet Bulb
SPH — Superheat at Compressor (F)

*Do not attempt to charge system under these conditions — refrig­

erant slugging may occur.

Table 8E — Superheat Charging Table, 48SX048

TEMP (F)

AIR ENT

EVAP AIR - CFM

1600

Evap Air — Ewb (F)

54

56

58

60

62

64

66

68

70

72

74

76

65

SPH

27 2

27.2

27.2

27.2

27.0

26.7

26.5

26.0

25.6

25 1

24 5

24.0

70

SPH

25 0

25.0

25.0

25.0

24.8

24 6

24.5

24.5

24.5

24 6

23.8

23.1

75

SPH

22 8

22 8

22 8

22.8

22.7

22 5

22.4

22 9

23.5

24.0

23.1

22.2

80

SPH

20 6

20 6

20.6

20.6

20.5

20 4

20.3

21.4

22.4

23.5

22 4

21.4

85

SPH

18.3

183

18.3

18.3

18.3

18.3

183

19.8

21.4

22.9

21 8

20.6

90

SPH

133

133

13.3

13.3

14.2

152

163

178

19 3

20.9

20 4

19.9

95

SPH

82

82

8.2

8.2

10.2

12 2

142

157

17.3

18.8

19.0

19.2

100

SPH

k

*

*

k

6.3

84

106

12 9

15.2

17.5

18.1

18 7

105

SPH

*

*

*

k

k

*

7 1

10 1

13.1

16.1

17.1

18 2

110

SPH

*

k

*

*

k

*

k

7 1

10.5

14.0

15.3

16.6

115

SPH

k

k

*

*

k

*

*

*

8 0

12.0

13 5

150

LEGEND

Ewb — Entering Wet Bulb
SPH — Superheat at Compressor (F)

*Do not attempt to charge system under these conditions — refrig­

erant slugging may occur.

35